TradeTools—Renegade & Renegade Industrial Portable Air Compressors

Identifying features

Assorted Models. Please visit www.tradetools.com/information-and-recalls for details.

What are the defects?

The maximum design pressure and hydrostatic test pressure stated on the name plates are incorrect and state higher pressures than calculated by design drawings.

What are the hazards?

There is a possibility that after any form of modification to the compressor, its safety features or the pressure vessel, consumers may exceed the maximum pressure of the tank and may cause a rupture to the pressure vessel, potentially injuring those surrounding.

What should consumers do?

Consumers must not modify their compressors, safety features or the pressure vessel so that they produce more than 990kpa (143psi) of maximum stored pressure. Owners and users of the affected compressors should visit their nearest TradeTools store to arrange for a new rating plate with the correct lower pressure values to be affixed to their compressors.

Supplier
Traders who sold this product

TradeTools Pty Ltd
TradeTools Regional Pty Ltd

Where the product was sold
New South Wales
Queensland
Victoria
Dates available for sale
  • 1 January 2013 - 14 June 2016

Recall advertisements and supporting documentation

Responsible regulator

Australian Competition and Consumer Commission is the responsible regulator for this recall.

Australian Competition and Consumer Commission
Product category