Orford Refrigeration—Hot Box Oven
What are the defects?
The ovens have been manufactured with incorrect wiring in the electrical panel. They have been wired with no thermal protection on the heating elements. The circuit needs to be modified so that the safety thermostat is in the same circuit as the heating elements. Under size 7.5 amp wire has been used to supply power to the relay contact. This needs to be upgraded to the correct 15 amp wire.
What are the hazards?
Electrical fire.
What should consumers do?
Orford will contact all customers who purchased the ovens and send an agent to the consumer's premises to repair/modify the defective ovens at no cost to the customer.
Supplier
Orford Refrigeration Pty Ltd
Where the product was sold
New South Wales
Queensland
Responsible regulator
Australian Competition and Consumer Commission is the responsible regulator for this recall.

Product category